This is the inside of a draft motor. This motor removes the carbon dioxide from your furnace and sends it uo the flu. It pulls the flames from the burners into the furnace. If it doesn't work right the flames will roll out the front of the furnace. The co2 won't go out the flu. This has three cracks. One at top right one bottom right and one bottom left. There wasn't much holding this together. This was a 20 year ild Ruud furnace. It was to expensive to repair. We replaced the furnace with a new Air Flo by Lennox. With a ten year parts warranty. For furnace repair in Henry co call Aaac service heating and air 7708754113.