another 33 year old furnace fixed

Image
 This one needed a new blower motor. Aaac Service had a motor in stock to resolve this issue fast. Older furnaces should be replaced. If you want it fixed we can do that as long as it is still safe to run. A carbon monoxide detector is recommended. For furnace repair in McDonough Ga call Aaac Service heating and air.  Issues we can fix fast The furnace tries to come on but it won't light The furnace flames come on but the blower doesn't The blower runs constantly but no heat The flames come on but go right out The thermostat clicks on but the furnace never starts The thermostat clicks on but the air conditioner won't start The fan comes on but its not cooling The fan on a/c isn't spinning The air conditioner is buzzing and won't come on The a/c makes a loud noise but doesn't start The ac has a humming but not coming on The air conditioner is running but not cooling  

Furnace is blowing cold air resolved

Image
The furnace fan is operational but it won't initiate the start sequence. A tripped limit switch was the issue. After resetting the limit switch, replacing the filter, and verifying airflow, the furnace is now functional. Our McDonough technician is available to service your Henry County gas furnace, even on Sundays. Understanding that you have numerous options for your home's heating and air conditioning needs, we, as a leading HVAC provider in Henry County, are committed to offering exceptional service, expert craftsmanship, and competitive prices. Our dedication to these principles is reflected in our expanding business, with the majority of our clientele being repeat customers.

Pilot light keeps going out.

Image
  Pilot won't stay on resolved A buildup of dirt in the intake valve restricts the oxygen your  furnace  needs to keep your pilot light going properly. To clean debris from the pilot light, use a wire brush, a paper clip or something similar to brush dirt and dust away from the pilot light mouth. Ok first if you have a standing pilot your  furnace  is over 25 years old. I can fix it. Second don't clean this I will do it and check out the furnace. $80 service calls in  Henry County . I can replace the furnace if needed. This one had to be scrapped the build up on the inside was terrible making it unsafe.